Assessment & Planning: We review your existing design, inspect mounting points and roof conditions, verify electrical ratings, and build a step‑by‑step plan aligned with roofing or construction timelines. We identify any parts that should be replaced, prepare materials, and schedule permits or utility notifications where applicable.
Safe Uninstall & Protection: After shutting down and verifying zero energy, we label conductors and equipment, record serials and array layouts, remove modules and racking, and protect penetrations with temporary weatherproofing. Components are packaged and stored to prevent scratches, moisture intrusion, or ESD damage.
Reinstall, Testing & Documentation: We refasten flashed mounts, set racking to spec, restore wiring with clean terminations and NEC labeling, and reinstall modules and balance‑of‑system equipment. Commissioning includes polarity checks, continuity and insulation resistance tests, inverter start‑up, and monitoring verification, followed by a site cleanup and final report.